Covidien Valleylab Force Triad Energy Platform ESU

Used

Used Covidien Valleylab Force Triad Energy Platform ESU

$5,700.00

Overview:
Unrivaled Versatility, Capability & Upgradeability

The ForceTriad energy platform is a full-featured electrosurgical system that provides electrosurgical cutting and coagulation, bipolar functionality, and vessel sealing in a single generator. The platform is intended for open and laparoscopic surgical procedures and includes:
- TissueFect sensing technology across all modalities
- Valleylab mode for electrosurgery
- LigaSure fusion technology for vessel sealing

The ForceTriad energy platform is the industry’s only full-featured energy platform with remote software upgrade capabilities. Using the Valleylab Exchange Software Update System, the unit can be easily updated on site, providing surgeons, nurses and patients with up-to-date, state-of-the-art technology.

Specialties utilizing the ForceTriad energy platform include:
- Colorectal
- Urology
- Orthopedics
- General Surgery
- Plastics
- Gynecology

Features
- TissueFect sensing technology is a Covidien control system designed to precisely manage energy delivery, creating a range of options for desired tissue effect
- Enhanced LigaSure™ tissue fusion technology permanently fuses vessels up to and including 7 mm, lymphatics, pulmonary vasculature and tissue bundles
- An optional bipolar resection with saline software application allows surgeons to perform a variety of urologic and gynecologic procedures in a saline environment
- Automatic instrument recognition
- All-in-one unit is compatible with conventional electrosurgical instruments and all current and new LigaSure™ instruments
- Fusion cycles are faster than the original LigaSure™ vessel sealing generator
- Valleylab mode provides a unique combination of monopolar hemostatis and dissection
- PER of 98 in Cut
- Connects with RapidVac smoke evacuator
- Adaptive REM system.

General:
- Output Configuration: Isolation output.
- Cooling: Natural convection and fan.
- Display: Three LCD touch screens.
- Connector ports: LED illuminated Smart connector readers
- Force Triad energy platform cart (FT900) Universal.
- Mounting cart (UC8009), and/or the UC8010 Over-shelf.
- Operating room boom systems.
- Any Stable, flat surface such as a table or cart top.

Dimensions and Weight:
- Height: 25.5 cm (10 in.)
- Width: 45.8 cm (18 in.)
- Depth: 50.8 cm (20 in.)
- Weight: 13.6 kg (30 lbs)

Activation Tone:
- The audio levels stated below are for activation tones (cut, Valleylab, coag, bipolar, and LigaSure Modes) and alarm tones (REM and system alarms) at a distance of one meter.

Volume and Frequency
- Volume (adjustable): 45 to 65 dBA
- Frequency Cut: -660 Hz
- Valleylab: 800 Hz.
- Coag: 940 Hz.
- Bipolar: 940 Hz.
- LigaSure: 440 Hz.
- Duration: Continuous while the system is activated.

Alarm Tone:
- Volume (adjustable): >65 dBA.
- Frequency: -REM: 660 Hz.
- Regrassp: Two tones: High= 985 Hz, Low = 780 Hz.
- Seal Complete: 985 Hz.
- Error/System Alert: Beep tone = 1400 Hz.
Duration:
- REM: Two 1/2 second tones separated by 1/2 second for each REM event
- Reactivate/Regrassp: Four 175 msec tones-high, low, high–low separated by 1/2 second.
- Check Instrument: Six 175 msec tones – high, low, high low, high, low -Seal Complete: Two 175 msec tones separated by 175 msec for each Seal Complete event.
- Error/System Alert: Two 1/2 second tones separated by 1/2 second for each Error/ System Alert event.

REM Contact Quality Monitor:
- Interrogation frequency: 80 kHz ± 10 kHz
vInterrogation current: < 100µA
- Interrogation voltage: < 12V RMS

Acceptable Resistance Range:
- REM resistance measurements are ± 10% during RF activation and ± 5% when RF output is not activated.
- REM patient return electrode: 5 to 135 ohms or up to a 40% increase in the initial measured contact resistance (which ever is less).If the measured resistance is outside the acceptable range(s) noted above, a REM fault condition occurs.

REM Alarm Activation:
REM patient return electrode: When the measured resistance exceeds the standard range of safe resistance (below 5 ohms or above 135 ohms) or when the initial measured contact resistance increases by 40% (whichever is less), the REM alarm indicator enlarges and flashes red and yellow, a tone sounds twice, and RF output is disabled. The indicator remains illuminated red and yellow until you correct the condition causing the alarm. Then, the indicator illuminates green and RF output is enabled.

Autobipolar:
- The ForceTriad energy platform is equipped with an autobipolar feature that allows for automatic activation of bipolar energy.
- Note: The autobipolar electrode function requires the use of the Valleylab E0018 bipolar Instrument cord.
- Autobipolar Specificaitons:
- Interrogation frequency: 80 kHz ± 10 kHz.
- Interrogation current: < 100 µA.
- Activation impedance: 20 O to 500.
- Deactivation impedance: User selectable: 1,500 O 1,800 O or 2,200 O.
- Measurement accuracy: ± 14% of Full Scale activation impedance while keying active above 10 watts.
-  + 50%, -14% of full scale activation impedance while keying active at 10 watts or below.
- ± 5% of Full Scale activation impedance while keying inactive.
- Keying delay: User selectable in 500 msec increments from 0 sec to 2.5 sec

Duty Cycle:
- Under maximum power settings and rated load conditions, the ForceTriad energy platform is capable of operating a duty cycle of 25% defined as 10 seconds active and 30 seconds inactive, in any mode for a period of 4 hours.
- Caution : Use of duty cycles greater than 25% (10 seconds active followed by 30 seconds inactive) will increase the risk that heat build-up under a return electrode may be high enough toinjure the patient. Do not continuously activate for longer than one minute.

Low Frequency (50/60 Hz) Leakage Current:
- Enclosure source current, ground open <300 µA.
- Source current, patient leads, all outputs
- Normal polarity, intact ground: < 10 µA.
- Normal polarity, ground open: < 50 µA.
- Reverse polarity, ground open: < 50 µA.
- Mains voltage on applied part: < 50 µA.
- Sink current at high line, all inputs<50 µA

Input Power: 100-120 Volt
Maximum VA at nominal line voltage:
- Idle: 52 VA
- Bipolar: 450 VA
- Cut: 924 VA
- Coag: 530 VA
- Input Mains Voltage, Full Registration Range:90-132 Vac
- Input Mains Voltage, Operating Range:85-132 Vac

220-240 Volt.
Maximum VA at nominal line voltage:
- Idle: 52 VA
- Bipolar: 450 VA
- Cut: 924 VA
- Coag: 530 VA
- Input Mains Voltage, Full Registration Range: 208-264 Vac
- Input Mains Voltage, Operating Range: 170-264 Vac

100-120 Volt
Mains Current (Maximum):
- Idle: 0.4 A
- Bipolar: 2.0 A
- Cut: 7.0 A
- Coag: 4.0 VA
- LigaSure: 5.0 VA
- Mains Line Frequency Range (Nominal): 50 Hz to 60 Hz
- Fuses (2): 5mm x 20 mm A8, 250 V: Fast Blow
- Power cord: 3-prong hospital grade: Connector

220-240 Volt.
Mains Current (Maximum):
- Idle: 0.2 A
- Bipolar: 1.0 A
- Cut: 3.5 A
- Coag: 2.0 VA
- LigaSure: 2.5 VA
- Mains Line Frequency Range (Nominal): 50 Hz to 60 Hz
- Fuses (2): 5mm x 20mm A8, 250 V: Fast Blow
- Power cord: 3-prong hospital grade: Connector

Tested 100% tested Guaranteed working ready to use.
one-Covidien Valleylab Force Triad Energy Platform ESU wit 3.60 software.
- 1 LigaSure Footswitch E6008 (Black)
- 1 LigaSure Footswitch LSO300 (Purple)
- 1 LigaSure Footswitch E6019 (Blue)