Datascope CS300 Balloon Pump

Used

Used Datascope CS300 Balloon Pump

$3,900.00

Maquet Datascope CS300 Features:
The Maquet Datascope CS300 IABP with IntelliSense combines fiber-optic speed with automatic in vivo calibration. The result is faster time to therapy, faster signal acquisition, and faster adaptation to rate and rhythm changes. Maquet has the only fiber-optic IABP and catheter system that automatically calibrates in the patient after insertion and automatically recalibrates in vivo every two hours or sooner should patient or environmental conditions change.

- Faster inflation and deflation speed
- CS300 has true one-button start-up
- Automatically calibrates the fiber-optic pressure sensor in the patient and recalibrates every 2 hours or sooner should patient or environmental conditions change
- Automatically evaluates and selects the best lead and trigger source
- Automatically sets optimal timing
- Automatically adjusts to changes in patient conditions without clinician intervention
- A Maquet fiber-optic IAB catheter
- Conventional fluid-filled IAB catheters

Specifications:
Dimensions:
- Size on Cart: 43.1” H x 16.8” W x 22.3” D (109 cm H x 42.7 cm W x 56.6 cm D)
- Size off Cart: 26.9” H x 10.8” W x 20.5” D (68.3 cm H x 27.4 cm W x 52.1 cm D)
- Console Weight: 84.8 lbs. (38.4 Kg) nominal (includes S.D., CRM, and He tank)
- Monitor: 9.5 lbs. (4.3 Kg) nominal
- Hospital Cart Weight: 52.4 lbs. (23.8 Kg) nominal
- Internal Battery: 34 lbs. (15.4 Kg) nominal
- Storage Bag: 4.6 lbs. (2.1 Kg) nominal (includes doppler and doppler holder)
- UTS Version: Rugged base which attaches to docking station (DS)
- Dimensions: 30.0” H x 13.2” W x 22.5” D (76.2 cm H x 33.5 cm W x 57.2 cm D)
- Console Weight: 135.3 lbs. (61.4 Kg) (includes S.D., CRM, He tank, Monitor, Battery)
- Lightweight DS*: 17.8” (45.1 cm) x 20.0” (50.8 cm); 16.3 lbs (Suggested Option)

Environmental:
- Op. Temp.: 10°C - 40°C
- Op. Humidity: 5 - 95% (R.H.) non-condensing
- Op. Altitude: 0 - 12,000 feet (3,657 m); automatic altitude correction for IAB

- Service Diagnostics: Built-in software for system analysis and troubleshooting
- Modem Data Rate: Up to 9,600 baud
- Modem Certifications: Registered with FCC and accepted in ~ 89 countries
- Fiber-optic signal Detected when sensor is connected to receptacle acquisition:
- Low-level Fiber-optic Enacted when appropriate cable plugged in
- Pressure Output: (electrically isolated)
- Pressure Range: 0 to +300 mmHg (minimum)
- Accuracy: 4 mmHg or 4%, whichever is greater
- Frequency Response: DC to 26Hz + - 15% (+0 to -3dB)
- Excitation: 4 to 8 Volts DC minimum
- Noise: .2 mmHg rms (0 to 26Hz bandwidth)
- External Mon. Inputs: ECG: 1 V/mV (nominal); AP: 1 V/100 mmHg (nominal)
- ECG/BP Output: Phone Jack: ECG 1V / mV, BP 1V/100 mmHg
- Mains Voltage: 100-120 VAC ± 10% or 220-240 VAC ± 10%
- Mains Frequency: 50/60 Hz ± 3 Hz
- Internal Battery: 24 VDC (nominal), 17.2 Amp-hour, approx. 3 hrs. @ 90 bpm
- Battery Type: Maintenance free; Sealed lead-acid
- System Compressor: Dual head diaphragm pump with brushless DC motor
- IAB Helium (He+): Medical-grade; 99L Refillable (2200 psi) or 140L Disposable (2200 psi)
- He+ Endurance (nominal) 2 mos. continuous operation - 24 hrs./day
- Condensate Removal: Fully automatic condensate removal and disposal
- Color Display: Color TFT Liquid Crystal Display (LCD) 8.3”(21cm)W x 6.2”(15.8cm)H; up 45°, 10.4” diagonal (26.4 cm down 55°, right 70°, left 70° viewing angle; Rotates 330°; Tilts 180°; Detachable; Laptoplike closure for storage and protection; Remote monitor mount (optional)
- Preferences Menu: User may select display sweep speed (25 or 50 mm/sec), brightness (low, med., high); balloon wave form (on/off); ECG inflation markers (on/off); flashing alarms (on/off); printer preferences, set date and time)
- Operation Modes: Auto, Semi Auto, Manual
- ECG Trigger: Threshold dynamically adjusted by system for high sensitivity and selectivity of the R-wave detection; Minimum =120µV ± 20µV at normal gain; 40µV at max. gain
- Pressure Trigger: Default trigger threshold is automatically adjusted to 38% of the systolic pulse height; 7 mm minimum Manual threshold mode: User adjustable between 7 and 30 mmHg ± 3 mmHg
- Pacer A Trigger: R-wave detection (as above) except pacer blanking is extended to 100 ms
- Pacer V/A-V Trigger: V Pacer: fixed at rate up to 185 bpm (no demand pacing)
- A-V Pacer: fixed at rate up to 125 bpm (no demand pacing) with A-V intervals between 80-224 ms
- Internal Trigger: Variable mode: 40-120 bpm; Normal mode: 80 ± 1 bpm
- Tall T-Wave Rejection: Rejects all T-Waves where Q-T interval is <300 ms (ECG and Pacer A mode) and the amplitude is <70% of QRS input amplitude
- Pacer Rejection: Rejects all pulses of amplitude ± 2.0 mV to ± 700 mV (ECG and Pacer A mode) and durations between 0.1 ms to 2.0 ms with: 1) No tail; 2) 100 ms time constant tail < 1 mV; 3) 25 ms time constant tail < 1 mV; 4) 4 ms time constant tail < 2 mV
- ECG Leads: In Auto Operation Mode: I, II, III, External
- In Semi-Auto Mode: I, II, III, AVR, AVL, AVF, V, External (12 lead compatibility)
- ECG Gain (default): 1 V output per 1 mV input ±5% (waveform automatically scaled to occupy ECG display window)
- Gain (variable): 0.15 to 3.0 cm/mV ±20% (autoscaling disabled)
- Frequency Response: 0.5-12 Hz (display); 0.5-135 Hz (Output to External Monitor)
- Defibrillator Protection: Discharge level ?? 360 J (trace returns to screen in 5 sec max)
- ESIS: Automatic suppression with internal ECG amplifier
- AP Source Selection: Direct/External (menu based)
- AP Input Sensitivity: 5.0µV/V/mmHg
- Excitation: +5 VDC ± 5% @ 130 mA (max)
- Frequency Response: DC to 12 Hz (display)